Built for every electrolyser chemistry. Engineered for your project.
Yonder's Power Core delivers precision DC output matched exactly to your electrolyser's sensitivity envelope, whether you're running Alkaline, PEM, AEM, or SOEC.
Grid to electrolyser: the converter chain
Grid interfaceGrid interface and isolation. Oil or dry (VPI) types up to 25 MVA and 33 kV, with 2–27 windings and custom vector groups.
Learn more
BaseloadProven robustness for high-current, stable baseload applications. Highly serviceable, cost-effective for predictable power demand profiles.
Learn more
Most specifiedMost specified for modern MW-scale projects. High power factor, exceptionally low harmonic distortion, rapid response to grid variability.
Learn more
EU / AEMNext-generation switching efficiency in an ultra-compact footprint. Deployed on cutting-edge AEM platforms in Europe.
Learn moreTransformer range
Oil filled transformer built for rectifier feed, with harmonic-aware winding arrangements.
- Rating
- Up to 25 MVA
- Voltage
- Up to 33 kV
- Pulse
- 6 / 12 / 24
- Cooling
- ONAN / ONAF
- Winding
- Aluminium or copper
- Tapping
- Off-circuit or OLTC
- Standards
- IS 2026, IEC 60076, IEC 61378
- Supply
- 3 phase, 50/60 Hz
Oil filled transformers for plant supply and converter feed across the full kVA to MVA span.
- Rating
- 630 kVA to 25 MVA
- Voltage
- Up to 33 kV
- Cooling
- ONAN / ONAF
- Winding
- Aluminium or copper
- Fluid
- Mineral, silicone or ester
- Sealing
- Conservator or hermetically sealed
Dry type cast resin unit for indoor and space-constrained sites, in two variants.
- Rating
- Up to 5 MVA
- Voltage
- Up to 33 kV
- Cooling
- AN / AF
- Insulation
- Class F / H
- Protection
- IP00 to IP44
- Variants
- Distribution or converter duty
- Pulse
- 6 / 12 / 24
Dry type vacuum pressure impregnated unit for compact indoor and outdoor installations.
- Rating
- Up to 2.5 MVA
- Voltage
- Up to 6.6 kV
- Cooling
- AN / AF
- Insulation
- Class F / H
- Phase
- 1 or 3 phase
- Protection
- IP00 indoor, IP54 outdoor
Why IGBT? The Case for Active Front End Power Conversion
Our AFE+Chopper IGBT architecture delivers measurable advantages over traditional thyristor-based converters, especially for modern MW-scale hydrogen plants connected to variable grids.
- Power Factor
- >0.99 with active control, no passive filter neededThyristor · ~0.95, passive filter required
- THDi (Grid Current)
- <2.5%, PWM controlledThyristor · 5–12%, needs a 24-pulse transformer to get below 3%
- Harmonic Control
- Fully active and adaptive, can compensate grid harmonicsThyristor · Fixed, depends on transformer configuration
- DC Bus Response
- Fast, ~500 Hz bandwidthThyristor · Slow, ~100 Hz firing angle control
- Efficiency at Part Load (40%)
- Higher, more efficient at partial loadsThyristor · Lower at part load
- Transformer Cost
- ~40% lower, uses a single-winding distribution transformerThyristor · Requires a multi-winding transformer
- Grid Compatibility
- Excellent, IEEE 519 compliant out of the boxThyristor · Needs additional filtering for IEEE 519
- System Cost
- Comparable overall, with more flexibility and simpler maintenanceThyristor · Lower component cost but higher transformer and filter costs
Thyristor converters remain a proven, robust choice for stable baseload applications. Yonder offers both architectures and recommends the right fit for your project's grid profile and operational requirements.